Description
4-20mA output proportional to peak or RMS acceleration vibration
5, 10, 20, or 50g full-scale measurement range
±5% tolerance at full scale
Frequency response:
±10%: 10Hz to 1kHz
±3 dB: 1Hz to 2kHz
±2% repeatability
700Ω max loop resistance at 24VDC
250g peak vibration limit
2,500g peak shock limit
Hermetic sealing
ESD, overload, and reverse wiring protection
PZT ceramic/shear sensing element
Top exit, 2-pin, MIL-C-5015 style output connector
R6-type mating connector