Dynamic vibration (IEPE) sensor output
Sensitivity:
376/CC701HT system: 100mV/g
376 sensor: 25 pC/g
Sensitivity tolerance:
376/CC701HT system: ±10%
376 sensor: ±5%
Frequency response:
376/CC701HT system:
±10%: 2 to 10,000Hz
±3 dB: 1 to 15,000Hz
376 sensor:
±5%: 6,000Hz
±10%: 8,000Hz
±3 dB: 12,000Hz
30kHz resonance frequency
500g peak vibration limit
5,000g peak shock limit
Sensing element design:
376/CC701HT system: PZT, compression
376 sensor: PZT ceramic / compression
1/4-28 tapped hole mounting