Ultra‐compact transmitter
Multivariable measurement for flow, temp, conductivity
-4 to 302°F (-20 to 150°C) medium temp ranges
0.015 to 2650 gal/min measuring range
Outputs:
4 to 20 mA HART (active)
Pulse/frequency/switch output (passive)
Maximum Measured Error:
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (optional): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
DN 2 to 150 (1/12 to 6in)) nominal diameter range
PN 40, Class 150, 20K maximum process pressure
No pressure loss due to cross-section constriction
4-line backlit display
IP66/67, Type 4X standard enclosure
ATEX, IECEx, cCSAus, INMETRO, EAC hazardous area approvals
Predecessors: Promag 50H, Promag 53H